Standard and optional features, Factory-installed options, Nomenclature – Heatcraft Refrigeration Products CLIMATE CONTROL CC-CUBZTB User Manual

Page 12

background image

12

Single

Ver

tic

al A
ir D
ischar

ge C

ondensing Unit

Standard and Optional Features

The Floating Tube™ coil design. Refrigerant-carrying copper

tubes do not contact any metal support sheets; instead,

the coil is constructed with expanded anchor tubes that

support the coil construction and do not carry refrigerant.

The coil design eliminates one of the major causes of leaks in

refrigeration systems

Limited five-year warranty against condenser tube sheet and

center support leaks

Designed for use with R-404A, R-507

Prebent copper tubes minimize welded joints on

internal piping

All sweat type connections, no flare joints to leak

Fixed high pressure switch eliminates capillary tubes

Oil safety control

Bitzer compressors with POE oil

Spring mounted compressor with suction and discharge

vibration eliminators

Crankcase heater

Thermally protected, permanently lubricated ball bearing

condenser fan motors

Separate subcooling circuit in condenser for added capacity

and vapor-free liquid

Receivers are sized for sufficient pumpdown capacity with

inlet and outlet service valves

Pressure relief valve on receiver

Sealed liquid line filter drier and sight glass

Electrical controls, including compressor contactor and

optional defrost control, are located in easily accessible

control box with a hinged cover

Service Mate

module to assist troubleshooting

Pumpdown Switch

Cabinet is constructed from prepainted galvanized steel

Convenient access panels for easy servicing to internal

components

Adjustable head pressure control valves

Factory-Installed Options

Compressor unloading

Replaceable core liquid filter drier

Liquid line solenoid valve

Suction filter

Replaceable core suction filter

Suction accumulator

Oil separator with discharge line check valve

Air defrost timer

Electric defrost kits, including timer, evaporator fan contactor

with fusing, defrost heater contactor(s), lockout relay and

terminal strip

Fusing for defrost kits

Evaporator holdout relays for systems with multiple electric

defrost evaporators

Low ambient kit with heated and insulated receiver with

time delay

Fused disconnect switch

Non-fused disconnect switch

Phase-loss protection

Manual-reset high pressure switch

Anti-short cycle timer

Compressor circuit breakers

Condenser fan cycling (standard on CDVS)

Three-way heat reclaim valve (n/a on CDVS)

Coated condenser coils for protection against corrosion in

harsh environments

Beacon II

compatible

Vertical Air Discharge Condensing Units 13 to 50 HP

Single Compressor

Nomenclature

C

D

V

000B

L

6

C

Brand

Airflow

Horsepower

Temp. Range

Refrigerant

Voltage

C =

Climate

Control

D -

V = Vertical
VS = Vertical Beacon

II

130B - 13
150B - 15
200B - 20
220B - 22
250B - 25
300B - 30
330B - 33
350B - 35
400B - 40

500B -50

M = Med. Temp.

L = Low Temp.

6 = R-404A,

R-507

C = 208-230/3/60
D = 460/3/60
E = 575/3/60