Operation instruction

Sleep operation

Use of SLEEP function

After turning on the unit, setting the working mode, then press SLEEP button
to make the air conditioner have the previous Sleep time (powered on for the
first time or after performing Sleep is 1h). The Sleep symbol will appear. Press
time */* button, you can choose between 1~8h. Each press, it may
increase/decrease 1h and will display in the humidity area with ìxhî, and display
ìTimer Offî in Timer Off area and the time to turn off; press Sleep button again
to cancel Sleep function. The Sleep symbol disappears.

Before going to bed, you can press the SLEEP button, the air conditioner will
operate in comfort sleep mode to make you have a sound sleep.
Before using this function, you should calibrate the clock first, otherwise, the
SLEEP function will be out of order

.

2.In HEATING operation

1 hour later in SLEEP operation, the
temperature will decrease 2* from the set
temperature, another 1 hour later increase
another 2*, then the unit will operate
continuous at this temperature for 3 hours,
then it increases 1*, after operating at this
temperature for another 3 hours, the unit will
turn off automatically. The temperature is
lower than set temperature to prevent you
from feeling uncomfortable during sleep.

Operation modes

1.In COOLING, DEHUMIDIFYING operation

1 hour later in SLEEP operation, the
temperature will increase 1* from the set
temperature, another 1 hour later increase
another 1*, then the unit will operate
continuous for 6 hours, then it turns off
automatically. The temperature is higher than
set temperature to prevent you from getting
a cold.

Note:

lAfter setting Sleep function, it is not permitted to adjust clock.
lThe Sleep time is less than 8h, after reaching the set time, the unit will automatically stop.
lSet Sleep function after setting ìTimer Offî function, the air conditioner will perform
Sleep function.
lAfter setting Sleep function, the Timer function cannot be set.
lSet Sleep function after setting ìTimer Onî function, the Sleep function can only be set
in the set time of Timer On.

Set temperature

SLEEP operation starts SLEEP operation stops

turn off

1 hour

about 3 hours

3 hours

decrease 2*

increase 1*

in HEATING operation

1 hour

decrease 2*

in COOLING* DEHUMIDIFYING operation

Set temperature

SLEEP operation starts

SLEEP operation stops

turn off

1 hour

about 6 hours

increase 1*

1 hour

increase 1*

10