Installation instructions – Hotpoint X156G User Manual
Page 19
Installation Instructions
19
The cooker can be close fitted below hotplate level. This requires a
minimum distance of 503mm between cupboard units of
hotplate height.
When installing next to a tall cupboard, partition or wall, for a minimum
distance of 400mm above hotplate level, allow a side clearance of
at least 65mm.
The diagram below illustrates the minimum clearance between the
cooker and adjacent walls, cupboards etc.
The wall behind the cooker 150mm below the hotplate and 450mm
above, and the width of the cooker, must be a non-combustible
material such as ceramic wall tiles.
If the cooker is to be fitted close to a corner on the left hand side,
ensure that there is a clearance of at least 50mm to allow the main
oven door to open fully for when removing oven shelves.
If a cooker hood is to be installed, refer to the cooker hood
manufacturers’ instructions regarding fixing height.
Cooker Hoods