beautypg.com

Installation instructions – Hotpoint X156G User Manual

Page 17

background image

Installation Instructions

17

Prior to installation, ensure that the local distributions (nature of
the gas and gas pressure) and the adjustment conditions are
compatible. The adjustment conditions for this appliance are
stated on the data badge which is fitted below the oven door on
the plinth panel. This appliance is not designed to be connected to
a combustion products evacuation device. It must be installed and
connected in accordance with current installation regulations.
Particular attention should be given to the relevant requirements
regarding ventilation.

MODEL NUMBERS X156G, 5TCG
Category

I

2H

(

G.B. IE)

These models are set to burn NATURAL GAS (G20) at 20 mbar ONLY
and cannot be used on any other gas.

It is the law that all gas appliances are installed by competent persons
in accordance with the current edition of the above regulations. It
is in your interest and that of safety to ensure compliance with the
law.

In the UK, CORGI registered installers work to safe standards of
practice.

The cooker must also be installed in accordance with BS 6172.

Failure to install the cooker correctly could invalidate the warranty
liability claims and could lead to prosecution.

The cooker may be located in a kitchen, kitchen/diner or a bed-sitting
room, but not in a room containing a bath or shower. The cooker
must not be installed in a bed-sitting room of less than 20m

3

The room containing the cooker should have an air supply in accordance
with BS 5440: Part 2

The room must have an opening window or equivalent; some rooms
may also require a permanent vent. If the room has a volume
between 5 and 10m

3

, it will require an air vent of 50cm

2

effective

area unless it has a door which opens directly to outside. If the
room has a volume of less than 5m

3

, it will require an air vent of

100cm

2

effective area. If there are other fuel burning appliances in

the same room, BS 5440: Part 2 should be consulted to determine
air vent requirements.

Gas Safety
(Installation & Use)
Regulations

Location

Provision for
Ventilation