beautypg.com

Maintenance and servicing, Cleaning, maintenance, and lubrication, Troubleshooting – Harbor Freight Tools Drill Master 18V 3/8" Cordless Drill 67024 User Manual

Page 9

background image

SKU 67024

For technical questions, please call 1-800-444-3353.

Page 9

Note: Ni-Cd BATTERY MUST BE

10.

RECYCLED OR DISPOSED OF

PROPERLY. Do not short, incinerate

or open Battery Pack.

maIntEnanCE anD

SERVICIng

Procedures not specifically

explained in this manual

must be performed only by a

qualified technician.

tO pREVEnt

SERIOuS InjuRY

FROm aCCIDEntaL

OpERatIOn: turn off tool and

remove Battery before

performing any inspection,

maintenance, or cleaning

procedures.

tO pREVEnt SERIOuS

InjuRY FROm tOOL

FaILuRE: Do not use

damaged equipment. If

abnormal noise or vibration

occurs, have the problem

corrected before further use.

Cleaning, maintenance, and

Lubrication

BEFORE EaCH uSE,

1.

inspect the

general condition of the tool. Check

for loose hardware, misalignment or

binding of moving parts, cracked or

broken parts, damaged electrical wir-

ing, and any other condition that may

affect its safe operation.
aFtER uSE,

2.

wipe external surfaces

of the tool with clean cloth.
When storing, always store Impact

3.

Wrench in clean, dry and safe loca-

tion out of reach of children.

troubleshooting

problem

possible Causes

Likely Solutions

Tool will not start.

Battery not charged.

Charge Battery.

Hammer function not

available.

Selector Ring in drilling position. Slide Selector Ring into hammering position.

Performance

decreases over time.

Accessory dull or damaged.

Keep accessories sharp. Replace as needed.

Excessive noise or

rattling.

Internal damage or wear.

Have technician service tool.

Overheating.

Forcing tool to work too fast.

1.

Accessory dull or damaged.

2.

Blocked motor housing vents.

3.

Allow tool to work at its own rate.

1.

Keep cutting accessories sharp. Replace

2.

as needed.
Wear ANSI-approved safety goggles and

3.

NIOSH-approved dust mask/respirator while

blowing dust out of motor using compressed

air.

Follow all safety precautions whenever diagnosing or servicing the

tool. Disconnect power supply before service.