beautypg.com

12. connecting input power, A. placing jumper links, 220 volts – Hobart Welding Products BETASTICK 500 User Manual

Page 22: 380 volts, 440 volts

background image

OM-201 444 Page 18

3-12. Connecting Input Power

A. Placing Jumper Links

Tools Needed:

3/8 in

ssb5.1 2/92 – Ref. ST-800 042

1

2

Jumper links allow operation on dif-
ferent input voltages and are facto-
ry set for the highest input voltage.

Check input voltage available at
site.

Open rear panel access door to
check jumper links.

1

Input Voltage Label – Only
One Is On Unit

Look at jumper links and compare
link position with unit label.

2

Input Voltage Jumper Links

Move links to match input voltage.
For example, use 230 volts position
when 230 volts input power is avail-
able.

Close door or go on to 3-12B.

220 VOLTS

S-021 148-A

L1

L2

L3

380 VOLTS

L1

L2

L3

440 VOLTS

L1

L2

L3