M. Air Shutter Setting

Air shutter settings should be adjusted by a qualifi ed
installer at the time of installation. The air shutter is set at
the factory for minimum vertical vent run. Adjust air shut-
ter for longer vertical runs. See Figure 15.24.

• Pull the air shutter knob up to close.
• Push the air shutter knob down to open.

NOTICE:

If sooting occurs, provide more air by opening

the air shutter.

Open

Closed

Figure 15.24 Air Shutter Adjustment