4-2. TROUBLESHOOTING
(Continued)
Problem
Cause
Correction
Green compressor indicator
Voltage across terminals 10-11
light off and compressor
of control board:
is working.
- Control board relay bad
Replace control board.
No voltage across terminals 10-11
of control board:
- Faulty contactor.Replace contactor.
Green fan indicator light
Voltage across terminals 8-9 of
on and fan(s) not working.
control board.
- Fan or capacitor bad
Replace fan or its capacitor.
- Fan thermo-switch tripped.
Allow the fan motor to cool to
see if the fan comes back on.
If the fan does not come back
on, or it keeps tripping, re-
place the fan.
No voltage across terminals 8-9
of control board:
- Faulty control board relay.
Replace control board.
All indicator lights off and
Check electrical supply.
Plug unit into receptacle, or
On/Off switch will not
reset wall circuit breaker.
operate.
Fuse of control board blown.
Change the fuse.
No voltage from the control
Change the control board.
board transformer.
Connector between the control
Check the connection.
board and display board not
connected properly.
Bad wire in the connector between
Replace the connector.
the control board and display
board.