beautypg.com

Harbor Freight Tools 86 User Manual

Page 8

background image

Page 8

SKU 00086

For technical questions, please call 1-800-444-3353.

MAINTENANCE

General Maintenance

Checking & Replacing the Needle

Needle wear is expexcted and inspection during Cleaning will ensure the continued top-

performance of your Touch-Up Gun. If needle tip wear is noted:

Step 1.

Unscrew the FAN ADJUSTING

SCREW (#28) and remove the

SPRING (#27).

Step 2.

Using a pair of pliers or other

suitable device, carefully pull and

twist the NEEDLE ASSEMBLY

(#24”S”) until it has been removed.

Step 3.

Purchase an identical replacement NEEDLE ASSEMBLY from Harbor Freight

Tools.

Step 4.

By hand, carefully insert the needle into the GUN HOUSING (#5) and push until

the tip has exited the hole in the AIR CAP (#1).

Step 5.

Place the SPRING over the NEEDLE ASSEMBLY and insert it into the

SPRAYER HOUSING.

Step 6.

Replace the ADJUSTING SCREW and readjust its setting to the position it was in

before removed (refer to Step 1).

NOTE (Step 1)

Before unscrewing the

ADJUSTMENT SCREW, place a mark on the

ADJUSTMENT SCREW where it meets the

GUN HOUSING (#13). This will make re-

adjusting the gun, after maintenance, easier.