To initialise the satellite position saved at Motor Antenna, set DiSEqC Command Mode to "Installer", set "Motor Control" to "Reset",
then press the OK button. You will see a warning message. To continue the procedure, press the OK button.
To set the motor position for each satellite manually, select the Satellite Name, set DiSEqC Command Mode to "Installer", and then
set Movement to one option among "East", "Stop", or "West". The motor starts moving. The level of signal strength and quality bar at
the bottom of the screen will indicate the best position of the dish. Set Motor Control to "Store" when you find the best position, then
press the OK button to save the position.
To move the motor to the pre-set position of the satellite, select the Satellite Name, set DiSEqC Command Mode to "User", set Motor
Control to "Goto", and set Movement to the desired value. Movement is used to fine-tune the position of the motor. Press the OK
button. the motor will move to the position of the selected satellite.
**
4.4 Motor Limit Setting
To enter this menu, press the RED button in Satellite Setting menu. You can set the maximum for both East and West to prevent
damage to the antenna.
**
•
Limit Setting: When Limit setting is set to "Enabled", the motor does not
move exceeding the limit. When Limit setting is set to "Disabled", the setting
is released.
•
Movement: You can select one among "East", "Stop", or "West".
•
Store East Limit: You can save the East Limit.
•
Store West Limit: You can save the West Limit.