Installation of molded brick panel – Hearth and Home Technologies BIR42-B User Manual
Page 38

38
11
Installation of Molded Brick Panel
A. Install Hearth Molded Brick Panel
• Place hearth panel into the fireplace.
B. Install Back Molded Brick Panel/Traditional
• Remove screen rods
• Remove the smokeshield
• Refer to Figure 11.1.
• Set the grate brackets in place, 26.5 in. (673 mm) center
to center.
• Install the back panel. Center from side to side.
• Install two Z-brackets in the mortar lines across the top.
Tighten these and all previously installed brackets.
C. Install Side Molded Brick Panel/Traditional
• If a gas line is to be installed, remove the knockouts in
the inner firebox and in the outer shell on the side of
your choice. Refer to dimension drawings for location of
knockouts and Section 13.A. for gas provisions.
• Install side panel, tapered edge to the front. Align the front
edge with the front of the column (or butted to the surround
if installed).
• Install two Z-brackets in the mortar lines across the top.
Tighten these and all previously installed brackets.
• Install second side panel following the steps above.
• Replace the smokeshield.
Figure 11.1 Traditional Molded Brick Panel
LH Traditional Refractory
Back Traditional Refractory
Hearth
Refractory Clip
Heatilator • Birmingham BIR42-B • 4059-681C • 9/12