Air filter maintenance – Honeywell HW2000i User Manual
Page 29

HW1000i / HW2000i Inverter Generator Owner’s Manual
www.honeywellgenerators.com
23
Air Filter Maintenance
Air Filter Maintenance
Air Filter Maintenance
Clean the air cleaner filter every 50 hours of generator
operation. If the generator is operated in extremely dusty
areas, clean the air filter more frequently.
1.
Stop the generator if the engine is running. Allow to
completely cool.
2.
Remove back maintenance cover (A), air filter cover
(B), and air filter (C).
3.
Wash the air filter in a solution of household soap and
warm water.
4.
Using a clean, absorbent cloth, squeeze the air
cleaner element dry, being careful not to twist or tear
the filter.
5.
Soak the air filter in clean engine oil.
NOTICE
A dirty air filter will restrict air flow to the carburetor, which
may cause poor engine performance or damage.
Never run the generator without the air cleaner assembly
properly attached.
Gasoline and flammable solvents can cause fire or
explosion. NEVER use gasoline or flammable sol-
vent to clean air cleaner element.
• Use only household soap and water to clean the air fil-
ter.
To clean air filter, you will need:
Screwdriver handle
Screwdriver universal bit
Household soap and water
Clean, dry cloth
Clean engine oil
FIGURE 32: Air Filter Removal - HW1000i Model
WARNING
A
B
C
FIGURE 33: Air Filter Removal - HW2000i Model
FIGURE 34: Wash Air Filter
FIGURE 35: Dry Air Filter
FIGURE 36: Air Filter Oiling
A
C
B