System Unit
Dimensions (HxWxD)
(with feet/bezel)
3.38 x 17.54 x 26.01 in (8.59 x 44.54 x 66.07 cm)
Weight (approximate)
Maximum
60 lb (27.22 kg)
Minimum
47.18 lb (20.41 kg)
Input Requirements
(per power supply)
Rated Line Voltage
100-132 VAC, 200-240 VAC
Rated Input Current
10A (100VAC), 10A (120VAC), 6.1A
(200VAC)
Rated Input Frequency
50 to 60 Hz
Rated Input Power
1000/1056/1205 W
BTU Rating
BTU/HR
3490/3680/4150
Power Specifications
To review typical system power ratings use the Active Answers Power
Calculator which is available via the online tool located at URL:
.
To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest. Example: DL380 G5
- Click on: "Power Calculator" link. (You may need to scroll down to see it.)
Power Supply Output
Power
(per power supply)
Rated Steady-State Power 800/850/1000 W
Maximum Peak Power
800/850/1000 W
Temperature Range
Operating
50° to 95° F (10° to 35° C) at sea level with an
altitude de-rating of 1.8° F per 1000 ft (1.0° C
per 304.8 m) to 10,000 ft (3048 m) no direct
sunlight allowed. Maximum rate of change is 18°
F/Hr (10° C/Hr). Upper operating limit is
10,000 ft (3,048 m) or 70 Kpa/10.1 psia.
System performance may be reduced if operating
with a fan fault or above 30° C.
Non-operating
-22° to 140° F (-30° to 60° C) Maximum rate of
change is36° F/Hr (20° C/Hr). Upper non-
operating limit is 30,000 ft (9,144 m) or
30.3KPa/4.4 psia.
Maximum Wet Bulb
Temperature
101.7° F (38.7° C)
Relative Humidity
(non-condensing)
Operating
10% to 90% relative humidity (Rh), 28° C
maximum wet bulb temperature.
Non-operating
5% to 95% relative humidity (Rh), 38.7° C
maximum wet bulb temperature.
Acoustic Noise
Idle Minimum (Fixed Disk
Drives Spinning)
L WAd (BELS)
6.4
L pAm (dBA)
47
QuickSpecs
HP ProLiant DL380 Generation 5
Technical Specifications
DA - 12477 Worldwide QuickSpecs — Version 1 — 6/26/2006