beautypg.com

Castile pellet stove, C. vertical d. through the wall & vertical – Hearth and Home Technologies CASTILE-PMH1 User Manual

Page 14

background image

Page 14

250-6422E

September 1, 2008

R

Castile Pellet Stove

We recommend a minimum of 60 in.
(1524mm) vertical, however above the
eave is preferred.

Both installations are approved for
mobile home installations. Must use
3 or 4 inch (76 to 102mm) “L” or “PL”
listed pellet venting or listed double
wall pipe and Quadra-Fire Outside Air
Kit in mobile homes. Single wall pipe
is approved for residential installations
only.

C. Vertical

D. Through The Wall & Vertical

Firestop

Flashing

Rain Cap

6 in.

(152mm)

Min.

Non-combustible Hearth Pad

3 in. (76mm) Min.

Clean-out Cover

24 in. (610mm) Minimum

Ceiling Support

6 in. (152mm) Flue
Connector

6 in. (152mm) Class A
Chimney Connector
Adapter

3 in. to 6 in.
(76-152mm)
Top Vent Kit

Figure 14.1

Figure 14.2

Non-combustible Hearth Pad

Cleanout Cover

Tee

Wall Thimble

Support Bracket
every 60 in. (1524mm)

24 in. (610mm) minimum

Rain Cap

Flashing

2 in. (51mm) minimum

6 in. (152mm)
minimum

This manual is related to the following products: