3

Connection of the water supply

To carry this out, use the kit provided which contains all the

necessary elements for connection to the water supply.

To improve the performance of the Aqua Care, we

recommend that you fit a tap with a filter on the pipe for

the connection to the water system: in this way it will be

possible to manually interrupt the water supply during long

periods in which Aqua Care is not used.

! The water pressure inside the water system must be

between 0.8 bar and 8 bar.

! The appliance must only be connected to a water supply

suitable for drinking.

Aqua Care function

The refrigerator you have purchased is fitted with the Aqua

Care system which, thanks to an advanced filter system

with active carbons, provides your household with fresh,

filtered water.

! To improve the system’s performance, we recommend

that you follow the instructions contained in this manual

and in the assembly diagram provided with the kit.

Starting Aqua Care

After connecting it to the water system, installing the filter

(see Replacing Aqua Care filter) and switching on the

refrigerator (See Starting the appliance), it is necessary to

remove any air from the Aqua Care system:

1. Activate the AQUA CARE function

by pressing the correct button (see

Control panel).

2. Place a container under the

dispenser.

3. Hold the button down until the

water is dispensed.

4. Drain and discard three litres of

water.

! When using for the first time and each time the Aqua

Care system is not used for more than 1 week, it will be

necessary to drain and discard three litres of water.

Disposing of the plug

Cut off and dispose of the supplied plug if it does not fit

your socket. The cable should be cut as close as possible

to the moulded plug.

Remove the fuse.

WARNING:

To avoid a shock hazard do not insert the discarded

plug into a socket anywhere else.

Fitting a new plug

IMPORTANT:

WIRES IN THE MAINS LEAD ARE COLOURED IN

ACCORDANCE WITH THE FOLLOWING CODE...

Green and Yellow

- Earth

Blue

- Neutral

Brown

- Live

As the colours of the wires in the mains lead may not

correspond with the coloured markings identifying the

terminals in your plug, proceed as follows:

-

Connect Green and Yellow wire to

terminal marked

'E' or

or coloured Green and Yellow.

-

Connect Brown wire to terminal marked 'L' or coloured

red or brown.

-

Connect Blue wire to terminal marked 'N' or coloured

Black or Blue.

If a 13amp plug (BS 1363) is used it must be

fitted with a 13amp fuse. A 15amp plug must be protected

by a 15amp fuse, either in the plug or adaptor or at the

distribution board.

If you are in any doubt about the electrical

supply to your machine, consult a qualified

electrician before use.

CE Marking certifies that this appliance conforms to

the following EEC directives :

Low Voltage Equipment - 73/23/EEC & 93/68 EEC

Electromagnetic Compatibility 89/336/EEC, 92/31/EEC

& 93/68/EEC