beautypg.com

Warning, Maintenance procedures, Compressor pump oil maintenance – Harbor Freight Tools Gas Powered Two-Stage Air Compressor 67853 User Manual

Page 14: Adding oil

background image

Page 12

For technical questions, please call 1-800-444 3353.

Item 67853

Maintenance

WARNING

TO PREVENT SERIOUS INjURY FROM ACCIDENTAL

STARTING:

Turn the Power Switch of the equipment to its “OFF”

position, release tank air pressure, wait for the engine

to cool, and disconnect the spark plug cap before

performing any inspection, maintenance, or cleaning

procedures.
TO PREVENT SERIOUS INjURY FROM EqUIPMENT

FAILURE:

Do not use damaged equipment. If abnormal noise,

vibration, or excess smoking occurs, have the problem

corrected before further use.
Follow all service instructions in this manual. The

engine may fail critically if not serviced properly.

Maintenance Procedures

Many maintenance procedures, including any

not detailed in this manual, will need to be

performed by a qualified technician for safety.

If you have any doubts about your ability to

safely service the equipment or engine, have

a qualified technician service the equipment

instead.

Compressor Pump Oil

Maintenance

Check oil periodically for clarity. Replace oil if it appears

milky or if debris is present, or every 6 months, or

100 hours of runtime, whichever comes first. In harsh 

environments such as high heat or high humidity, you

will need to replace the oil more frequently.
Change the compressor oil after the first hour of

use to remove any debris.

Adding Oil

1.

Oil Sight Glass (19)

Crankcase (16)

OVERFILL

LOW

FULL

OIL LEVEL

The oil level should be at the center of the “full” level

on the Oil Sight Glass, as shown above. Add oil as

needed to maintain this level. Do not let the oil level

go below the center dot (LOW as shown above) and

do not overfill the oil so that it is above the center dot 

(OVERFILL as shown above) on the Oil Sight Glass.

2. To add oil:

a. Remove the Oil Plug (17).
b. Using a funnel to avoid spills, pour enough oil into

the pump Crankcase to reach the “full” level in the

Oil Sight Glass.

c. Replace the Oil Plug.

Cold Weather Operation

Premium quality 30-weight, non-detergent air

compressor oil (sold separately) is recommended for

use with this compressor. Start compressor in heated

area if outdoor temperatures drop below 32° F. If this

is not practical, drain out the old pump oil and use

SAE 10W Non-detergent Air Compressor Oil in the

pump crankcase instead whenever the compressor’s

temperature will fall below 40°. Do not use multi-

viscosity oil (such as 10W-30), they leave carbon

deposits on pump components and lead to accelerated

failure. Heavy operation may require heavier

viscosity oil.

3. If uncertain which oil to use for this compressor,

please call Harbor Freight Tools customer service at

1-800-444-3353 for assistance.

WARNING! To prevent serious injury from burns: Do not

add or change the oil while the compressor is in operation.

Allow the compressor to cool before replacing oil.