Pump performance – HONDA WMP20X User Manual
Page 5

5
NOTICE
Pumping liquids that are not listed may cause damage to the pump.
Agricultural Chemicals
Industrial Chemicals
PUMP PERFORMANCE
The maximum pump discharge capacity is determined when pumping
clear water at 0 ft (0 meters) total head and at sea level. As the total
head (discharge head + suction head) increases, pump discharge
capacity decreases (see figure). If the pump is used at higher
elevations, pump discharge capacity may also decrease. Other
factors affecting pump discharge capacity are:
• The type of chemical being pumped.
• The length and type of the suction and discharge hose used.
Oil Alert
®
System
The Oil Alert system is designed to prevent engine damage caused by
insufficient oil in the crankcase. Before the oil level in the crankcase
can fall below a safe limit, the Oil Alert system will automatically shut
down the engine (the ignition switch will remain in the ON position).
If the engine stops and will not restart, check the oil level (page 8)
before troubleshooting in other areas.
Aatrex
Dual
N-Serve 24
Amiben
Eradicane
Phosphoric Acid
Solutions
Ammonium
Thiosulfate
Extrazine
Poly-N
Banvel
Larsban
Ranger
Basagran
Lasso
Round-up
Bicep
URAN Solutions
Sutan
Bladex
Modown
Treflan
Vernam
Acetic Acid, 20%
Glycerine (Glycerol)
Sodium Acetate
Aluminum Sulfate
Lactic Acid
Sodium Bicarbonate
Ammonium Nitrate
Lead Acetate
Sodium Bisulfate
Ammonium Sulfate
Magnesium Chloride
Sodium Bisulfite
Barium Sulfate
Magnesium Nitrate
Sodium Carbonate,
10%
Borax (Sodium Borate) Magnesium Sulfate
Sodium Chlorate
* Calcium Chloride
Maleic Acid
Sodium Chloride
Citric Acid
Nickel Chloride
Sodium Nitrate
Copper Sulfate
Nickel Sulfate
Sodium Silicate
Detergents (General)
Oleic Acid
Sodium Sulfate
Ethylene Glycol
Phosphoric Acid,
0-80%
Stearic Acid
Fatty Acids
Potassium Carbonate Sulfuric Acid, 0-29%
Ferric Nitrate
Potassium Chloride
Tartaric Acid
Ferric Sulfate
Potassium Nitrate
Vinegar
Ferrous Sulfate
Potassium Sulfate
Water (Clear)
Formaldehyde, 40%
Soaps (neutral)
Water (Salt)
Zinc Sulfate
* Temperature does not exceed 80°F.
The temperature operating range of the pump is between
20 ~ 130°F (-7 ~ 54°C).
Pump Performance (Maximum with clear water)
Total head
105 ft (32 m)
Suction head
26 ft (8 m)
Discharge capacity
220 gal/min (833
/min)
Self-priming time
65 sec at 16.4 ft (5 m)
Pressure
45 psi (310 kPa)
DISCHARGE
HEAD
SUCTION
HEAD
TOTAL
HEAD