Glass, Log removal/replacement, System inspection – Hearth and Home Technologies NOVUS GNBC33 User Manual
Page 21: Novus b-vent installation instructions
12-02
21
34615 Rev G
NOVUS B-VENT INSTALLATION INSTRUCTIONS
3. VENTING SYSTEM INSPECTION
The appliance and venting system should be inspected
before use, and at least annually, by a qualified field
service person, to ensure that the flow of combustion
and ventilation air is not obstructed.
4. CLEANING THE GLASS
See Figure 29.
Never operate this appliance without the glass properly
secured in place or if the glass is broken.
In the event of glass breakage, carefully remove the
glass frame. This will allow the removal of all glass
fragments and sheet metal edge protection strips.
Vacuum all remaining glass pieces with a shop vac.
DO NOT VACUUM IF PIECES ARE HOT! Replace
glass with only a Heatilator glass panel assembly
ordered direct or through your local distributor. Never
use substitute material. Only fully tempered soda lime
safety glass may be used on this appliance.
5. LOG REMOVAL/REPLACEMENT
If removal of the logs becomes necessary, remove the
two screws at the front of the grate. Grasp the two outside
upright grate bars. Pull the log set toward the front and
up, off the burner. See Figure 30.
To replace the log set, grasp the two outside upright grate
bars. Push and lower the log set onto the burner pan,
making sure the back of the left most grate bar slides
through the grate mounting bracket attached to the
hearth pan. Attach the two screws at the front of the
grate.
Figure 29 - Glass Cleaning
Figure 30 - Log Removal
Safety Note:
Handle glass with care to
avoid striking, scratching or
slamming shut. NEVER
clean glass when hot. Keep
children and pets a safe
distance away.