beautypg.com

Glass, Log removal/replacement, System inspection – Hearth and Home Technologies NOVUS GNBC33 User Manual

Page 21: Novus b-vent installation instructions

background image

12-02

21

34615 Rev G

NOVUS B-VENT INSTALLATION INSTRUCTIONS

3. VENTING SYSTEM INSPECTION

The appliance and venting system should be inspected

before use, and at least annually, by a qualified field

service person, to ensure that the flow of combustion

and ventilation air is not obstructed.

4. CLEANING THE GLASS

See Figure 29.
Never operate this appliance without the glass properly

secured in place or if the glass is broken.

In the event of glass breakage, carefully remove the

glass frame. This will allow the removal of all glass

fragments and sheet metal edge protection strips.

Vacuum all remaining glass pieces with a shop vac.

DO NOT VACUUM IF PIECES ARE HOT! Replace

glass with only a Heatilator glass panel assembly

ordered direct or through your local distributor. Never

use substitute material. Only fully tempered soda lime

safety glass may be used on this appliance.

5. LOG REMOVAL/REPLACEMENT

If removal of the logs becomes necessary, remove the

two screws at the front of the grate. Grasp the two outside

upright grate bars. Pull the log set toward the front and

up, off the burner. See Figure 30.

To replace the log set, grasp the two outside upright grate

bars. Push and lower the log set onto the burner pan,

making sure the back of the left most grate bar slides

through the grate mounting bracket attached to the

hearth pan. Attach the two screws at the front of the

grate.

Figure 29 - Glass Cleaning

Figure 30 - Log Removal

Safety Note:

Handle glass with care to

avoid striking, scratching or

slamming shut. NEVER

clean glass when hot. Keep

children and pets a safe

distance away.

This manual is related to the following products: