NOVUS B-VENT INSTALLATION INSTRUCTIONS
1. Turn off all wall switches to the appliance. Set
thermostat to lowest setting
2. Open control access panel.
3. Turn manual shutoff valve to CLOSED. Wait 5
minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP! Follow
B in the safety information above on this label. If you
dont smell gas, go to the next step.
4. Turn manual shutoff valve to OPEN.
5. Turn pilot knob clockwise to OFF. Knob may have
to be depressed to pass the PILOT position.
6. Locate pilot assembly inside appliance.
7. Locate red ignitor button.
8. Turn pilot knob to PILOT and push in.
9. Continue to hold in pilot knob and push the red ignitor
button 12-15 times until small blue pilot flame appears.
10. Continue to hold in pilot knob for approximately one
minute. Pilot should remain lit. If pilot goes out, wait 5
minutes and repeat Steps 4-9.
11. Release and turn the knob counterclockwise to ON.
To light main burner, turn wall switch to ON. Do not
light by hand.
12. If the appliance will not operate, follow the instructions
To Turn Off Gas To Appliance and call your service
technician or gas supplier.
2. STANDING PILOT IGNITION
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbors phone. Follow the suppliers instructions.
If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn manual shutoff valve. Never use tools. If the manual shutoff valve will not push in or
turn by hand, dont try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or
explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any gas control which as been under water.
WARNING!
If you do not follow these instructions exactly, a fire or explosion may result causing property damage,
personal injury or loss of life.
LIGHTING INSTRUCTIONS
STOP! READ THE SAFETY INFORMATION ABOVE ON THIS LABEL!
Note:
To light main burner, turn the wall switch
to ON. Do not light by hand.
TO TURN OFF THE GAS TO THE
APPLIANCE
1. Turn off the wall switch or set thermostat to lowest
setting.
2. Open control access panel.
3. Turn the manual shutoff valve to CLOSED position.
Do not force.
4. Close control access panel.
FOR YOUR SAFETY READ BEFORE LIGHTING THE STANDING PILOT.