3. weld parameter chart for 230 vac model, 3, as applicable), Welding guide – Hobart Welding Products OM-944 196 639G User Manual
Page 26

OM-944 Page 22
5-3. Weld Parameter Chart For 230 VAC Model
Welding Guide
Settings
are approximate.
Adjust as required.
Thicker materials can be welded
using proper technique,
joint preparation,
and multiple passes.
Match feedroll groove to diameter of wire being used.
Set Tension Knob Setting to 3 at Start.
Adjust tension per instructions
in the manual.
**Aluminum
wire is relatively
soft so feedability
is not as good.
Make sure that hub tension
is not too tight and
CAUTION!
Do not change Voltage Switch
Knob position while welding.
Wire
T
ype,
and
Polarity Setting
Flux Core
E71T
−1
1
(DCEN)
Solid Wire
ER70S−6
(DCEP)
Solid Wire
ER70S−6
(DCEP)
Stainless
Steel
(DCEP)
Aluminum**
(DCEP)
Material
Being
Welded
Stainless
Steel
Aluminum
Suggested
Shielding Gas
20−30
cfh Flow Rate
T
ri−Mix
90% He/7.5% Ar/2.5% CO2
100% Argon**
100% CO2
No Shielding
Gas Required
Good for Windy or
Outdoor Applications
C25 Gas
Mixture
75% Argon / 25% CO2
Produces
less Spatter
Better Appearance
Diameter
of
Wire
Being Used
.030” (0.8 mm)
.035” (0.9 mm)
.045” (1.2 mm)
.024” (0.6 mm)
.030” (0.8 mm)
.035” (0.9 mm)
.024” (0.6 mm)
.030” (0.8 mm)
.035” (0.9 mm)
.024” (0.6 mm)
.030” (0.8 mm)
.035” (0.9 mm)
.030” (0.8 mm)
.035” (0.9 mm)
Steel