coNNecTIoN

warNINg!

risk of Fire!

The positive battery

terminal connection

must be the laST

connection and must

be done with the

inverter’s switch off.

For the power inverter to work properly, your power source must provide

12 volts DC, and the power source must provide enough current (i.e., 32 amps to

operate the load of 384 Watts or under).

Caution:

This inverter must only be connected to batteries with a nominal output

voltage of 12 volts. Lower voltage will not operate the inverter properly, and

more voltage could damage the inverter or the device being powered. If more

than one 12 volt battery is to be used, the batteries must be connected in a

parallel circuit; batteries connected in a series circuit will produce too much

voltage.
Place the Power Inverter on a flat surface. Make sure it has adequate venti-

1.

lation and is not in direct sunlight. Fasten the inverter securely to the surface,

using screws or some other means. If holes are to be drilled, follow safe,

proper installation techniques.
Connect the Battery Cable lugs to the (Positive) red and (Negative) black

2.

terminals on the back of the Inverter. Securely tighten.
The Power Inverter can be used either while the engine is running or off.

3.

Connect the Battery Cables to the Negative (black) and Positive (red) termi-

nals of the battery.