Warning, Connection, Risk of fire – Harbor Freight Tools 92708 User Manual
Page 5
SKU 92708
Page 5
For technical questions, please call 1-800-444-3353.
coNNecTIoN
warNINg!
risk of Fire!
The positive battery
terminal connection
must be the laST
connection and must
be done with the
inverter’s switch off.
For the power inverter to work properly, your power source must provide
12 volts DC, and the power source must provide enough current (i.e., 32 amps to
operate the load of 384 Watts or under).
Caution:
This inverter must only be connected to batteries with a nominal output
voltage of 12 volts. Lower voltage will not operate the inverter properly, and
more voltage could damage the inverter or the device being powered. If more
than one 12 volt battery is to be used, the batteries must be connected in a
parallel circuit; batteries connected in a series circuit will produce too much
voltage.
Place the Power Inverter on a flat surface. Make sure it has adequate venti-
1.
lation and is not in direct sunlight. Fasten the inverter securely to the surface,
using screws or some other means. If holes are to be drilled, follow safe,
proper installation techniques.
Connect the Battery Cable lugs to the (Positive) red and (Negative) black
2.
terminals on the back of the Inverter. Securely tighten.
The Power Inverter can be used either while the engine is running or off.
3.
Connect the Battery Cables to the Negative (black) and Positive (red) termi-
nals of the battery.
reV 06f