Cleaning

On an annual basis, maintenance is required to ensure TrueDRY runs at peak efficiency.

TrueDry DR65 Dehumidification System 69-2089EFS—11

11

1

2

3

4

Unplug TrueDRY DR65 before beginning
service. Press down on the quick-
release button and remove the duct
collar.

Remove filter (50049537-005) and
replace with new filter.

Using a 1/2-in. hex drive or standard
screwdriver, remove the three screws
on each side of the TrueDRY DR65. The
cabinet can then be removed. Using
a damp cloth, wipe excess dust and
debris from blower, refrigerant coils, and
compressor coils. Reattach cabinet and
collars when finished.

5

When service is complete, initiate a
call for dehumidification and check
that the compressor and fan activate.
If using the VisionPRO IAQ or TrueIAQ
controls, reset maintenance remind-
ers.

Check the drain connection and drain
line to ensure it is clear of debris and
sludge. Ensure all hose connections
are secure once maintenance of the
drain lines is complete.