Appendix parameter cross-reference list – Hitachi SJ-PB(T) User Manual
Page 31

APPENDIX PARAMETER CROSS-REFERENCE LIST
27
Code No. Size
Range
Magn.
Contents
L300P
Read/
Write
A045
213
1
20 100%
*1
Gain of output voltage
R/W
A051
214
1
00,01
code
Selection of DC braking method
R/WOS
A053
215
1
0 5.0s
*10
Delay time of DC braking start
R/WOS
A054
216
1
0 100
*1
Power of DC braking(end of running)
R/WOS
A056
217
1
00,01
code
Selection of edge/level action of
DC braking trigger
R/WOS
A057
218
1
0 100
*1
Power of DC braking(start of running)
R/WOS
A059
219
1
0.5 15.0kHz
*10
Carrier frequency of DC braking
0.5 12.0
R/WOS
A071
220
1
00,01
code
Selection of PID control presence
R/WOS
A072
221
1
0.2 5.0
*10
Proportional(P) gain of PID control
R/W
A076
222
1
00,01
code
Selection of feedback destination for
PID control
R/WOS
A081
223
1
00 02
code
Selection of AVR function
R/WOS
A082
224
1
0 10
code
Selection of Motor voltage
R/WOS
A085
225
1
00 02
code
Selection of operation mode
00,01
R/WOS
A094
226
1
00,01
code
Selection of 1st 2-stage accel/decel Method
R/WOS
A294
227
1
00,01
code
Selection of 2nd 2-stage accel/decel Method
R/WOS
A097
228
1
00 03
code
Selection of acceleration pattern
R/WOS
A098
229
1
00 03
code
Selection of deceleration pattern
R/WOS
A131
230
1
01 10
code
Curve constant of acceleration
R/WOS
A132
231
1
01 10
code
Curve constant of deceleration
R/WOS
b001
233
1
00 03
code
Selection of retry method
R/WOS
b002
234
1
0.3 1.0s
*10
Acceptable time for
Instantaneous power failure
R/WOS
b004
235
1
00 02
code
Selection of method(action) at instantaneous
power andunder voltage
R/WOS
b005
236
1
00,01
code
Retry number of instantaneous power
and under voltage
R/WOS
b006
237
1
00,01
code
Selection of fail phase function
R/WOS
b013
238
1
00 02
code
Selection of characteristic of
1st electronic thermal protection
R/WOS
b213
239
1
00 02
code
Selection of characteristic of
2nd electronic thermal protection
R/WOS
b313
240
1
00 02
code
Selection of characteristic of
3rd electronic thermal protection
No
R/WOS
b021
242
1
00 03
code
Selection of method of overload restriction1
R/WOS
b024
243
1
00 03
code
Selection of method of overload restriction2
R/WOS
b031
244
1
00 03,10
code
Selection of method of Software lock
R/WOS
b037
245
1
00 02
code
Selection of Display
R/WOS
b040
247
1
00 04
code
Selection of method of Torque limiter
No
R/WOS
b041
248
1
0 200%
*1
Level of torque limiter in forward
and drive (1st quadrant)
No
R/WOS
b042
249
1
0 200%
*1
Level of torque limiter in reverse
and regenerative (2nd quadrant)
No
R/WOS
b043
250
1
0 200%
*1
Level of torque limiter in reverse
and drive (3rd quadrant)
No
R/WOS
b044
251
1
0 200%
*1
Level of torque limiter in forward
and regenerative (4th quadrant)
No
R/WOS