beautypg.com

1 ppo- description, Chapter5 operating 10 – Hitachi SJ-PB(T) User Manual

Page 14

background image

CHAPTER5 OPERATING

10

This section describes how to control the inverter via control word/status word and how to access the inverters
parameters.

5.1 PPO- description

The structure of the user data is designated as parameter process data objects (PPO) in the Profidrive profile.
The profile defines five PPO types, where SJ-PB supports all these PPO types.
There are PPO’s with a parameter area (PKW) and a process data area (PZD). There is also PPO’s that consist
exclusively of process data (PZD).
1. PPO1 consists of the PKW area and 2 words PZD.
2. PPO2 consists of the PKW area and 6 words PZD.
3. PPO3 consists only of 2 words PZD.
4. PPO4 consists only of 6 words PZD.
5. PPO5 consists of the PKW area and 10 words PZD.

The user can configure what shall be transferred in PZD3-10 (shaded grey below), for more instructions of how to
do this configuration see chapter 5.3.3, 5.4.2, 5.4.3 and Appendix.

PKW

PZD

PKE

IND

PWE

PZD1

STW
ZSW

PZD2

HSW

HIW

PZD3

PZD4

PZD5

PZD6

PZD7

PZD8

PZD9

PZD10

Word

1

2

3

4

5

6

PPO1

Word

1

2

3

4

5

6

7

8

9

10

PPO2

Word

5

6

PPO3

Word

5

6

7

8

9

10

PPO4

Word

1

2

3

4

5

6

7

8

9

10

11

12

13

14

PPO5

PKW -- Parameter ID/value.
PZD -- Process data, cyclically transferred.
PKE -- Parameter ID (1

st

and 2

nd

octet).

IND -- Sub-index (3

rd

octet), 4

th

octet is reserved.

PWE -- Parameter value (5

th

to 8

th

octet, 32-bits).

STW -- Control word.
ZSW -- Status word.
HSW -- Main reference.
HIW -- Main actual value.