Page 7

SKU 41209

For technical questions, please call 1-800-444-3353.

5.

Connect the air supply to the tool at the Air Plug (17). Set the regulator at the
recommended 65 PSI to 100 PSI. Do not to go over the maximum 100 PSI.

6.

Test the tool by depressing the nose against the workpiece without pulling the
Trigger (42). The Tool must not cycle (fire). If it cycles (fires), stop immedi-
ately and have it repaired by a qualified service technician.

7.

Hold the tool away or off of the workpiece. The Nose (72) of the tool should
return to its original position. Squeeze the Trigger (42). The tool should not
cycle (fire).
If the tool fires, stop immediately and have it repaired by a qualified
service technician.

8.

Depress the Nose (72) against the workpiece and squeeze the Trigger (42). The
tool must cycle (fire).
Release the Trigger and squeeze it again. The tool must
cycle (fire).
With the Trigger held, carefully lift the Nailer and press it against the
workpiece again. The tool must cycle (fire). If it fails to perform in the manner
explained in bold, have it repaired by a qualified service technician.

Loading Coil Nails

ALWAYS WEAR ANSI APPROVED IMPACT SAFETY GOGGLES WHEN
RELOADING OR DOING ANY OTHER MAINTENANCE ON THIS TOOL.
Other people in the work area must also wear ANSI approved impact safety
goggles.

Warning! Make sure the Nailer is not attached to the air hose whenever loading
the tool.

NOSE (72)

TRIGGER (42)

AIR PLUG (17)