Installation – Harman Stove Company 3-90-70738 User Manual

Page 5

background image

5

INSTAllATION

wArNINg: This stove must be installed in accor-

dance with all state and local building code require-

ments.

locating the stove

Locate the stove as close to the chimney or flue as

possible, while still maintaining the clearances to com-

bustibles.

Locate the stove where there is sufficient air supply for

ventilation and proper combustion.

Clearance to Combustibles

Safe stove clearance to combustible walls is 24” to

the rear and 36” to the sides and front. Do not place

furniture and the like directly in front of the stove.

Floor Protection

Floor protection for a combustible floor should con-

sist of 3/8” millboard or a stove board providing equal

protection(k=.84, R=.45). The floor protection should

extend 8” to the rear and either side and 6” in front of

the stove. The floor protection should also extend 2” to

either side of the chimney connector, to the wall where

the connector enters the flue.

36”

8”

36”

8”

8”

16”

24”

Floor Protection

Floor Protection

Adjustable leveling Feet

To accomodate an un-even hearth surface, the SF250

is equipped with adjustable leveling feet. Each foot

can be turned in or out of the leg to lower or raise that

corner of the stove.

Turn the round foot in or out to

level each corner of the stove.

It is recommended that you have your unit installed

and serviced by professionals who are certified by the

National Firplace Institute (NFI) as NFI Specialists.