beautypg.com

If you have a problem, Lubrication, The agitator – Hoover C1404 User Manual

Page 8

background image

8

Pull belt off motor pulley as
shown.

Remove bottom plate as shown in
Fig. 29 of

“How to replace belt”.

Remove agitator from cleaner and
discard.

Reposition belt and new agitator by
referring to Figs. 31 to 35.

Place hood on cleaner body
and press to snap all four

latches. Pull up on hood slightly to
make sure all four latches are
secured.

The agitator

When to replace

Disconnect cleaner from electrical
outlet.
When agitator brushes are worn, the
agitator should be replaced.

To check condition of brushes, move
edge of a card across bottom plate
while turning agitator. To maintain
cleaning effectiveness, replace agi-
tator if brushes do not touch card.

Stretch new belt onto motor
pulley (F).

Extra effort may be required to
stretch belt onto pulley.
Turn agitator, making sure belt is not
pinched between agitator and
cleaner body. The belt must rotate
freely inside the belt guide. If the
agitator does not turn, remove bot-
tom plate and reposition belt in the
belt guide.

What to buy

The agitator may be replaced with
part

No. 48414-155.

How to replace

Disconnect cleaner from electrical
outlet.

Remove hood as shown in Figs. 33
and 34 of

“How to replace belt”.

35

35

36

36

37

37

F

If you have a
problem

If a minor problem occurs, it usually can

be solved quite easily when the cause is

found by using the checklist below.

38

38

G

Possible cause
Possible solution

• Not firmly plugged in
Plug unit in firmly
• No voltage in wall plug
Check fuse or breaker
• Blown fuse/tripped breaker
Replace fuse/reset breaker

Possible cause
Possible solution

• Broken or worn belt
Replace belt
• Brush roll brushes worn
Replace brush roll
• Filter bag full
Change filter bag

Problem: Cleaner won’t run

Problem: Cleaner won’t pick up

Lubrication

The motor is equipped with bearings
that contain sufficient lubrication for
the life of the motor. The addition of
lubricant could cause damage.
Therefore, do not add lubricant to
motor bearings.

The agitator is equipped with two
ball bearings that should be lubricat-
ed periodically by a Hoover Factory
Service Center or an Authorized
Hoover Warranty Service Dealer.

Turn cleaner over and lift off
hood.

34

34