V

H

1' MIN. (305mm)

2' MAX. (610mm)

2' MIN. (610mm)

4' MAX. (1.22m)

3' MIN. (914mm)

6' MAX. (1.86m)

4' MIN. (1.22m)

8' MAX. (2.4m)

V+H=40' MAX. (12.4m) H = 8' MAX. (2.4m)

NOTE: On vertical venting configurations where
the vertical component is over 10 feet, you may
want to install the vertical baffle included in the
manual bag assembly to improve flame
appearance.

Figure 11. Venting with One 90° Elbow

VENTING WITH ONE (1) 90° ELBOW

VENTING WITH ONE (1) 90° ELBOW

V (FT.)

H (FT.)

1' MIN. (305mm)

5' MAX. (1.52m)

2' MIN. (610mm)

10' MAX. (3.1m)

3' MIN. (914mm)

15' MAX. (4.65m)

4' MIN. (1.22m)

20' MAX. (6.2m)

V+H= 40’ MAX. (12.4MM) H = 20' MAX. (6.2m)

Figure 12. Venting with One 90° Elbow

NOTE: If a 90

o

elbow is first attached to the unit,

the maximum horizontal run is 3-feet (914mm).

NOTE: For corner installations: A 6-inch (152mm)
section of straight pipe may need to be attached to
the fireplace before a 90

o

elbow, to allow the vent

pipe to clear the top standoffs.

H