Operation – Husqvarna 966061401 User Manual
Page 32
OPeRaTION
32
Press in and turn the ignition key to the start
9.
position.
Propane models - the lockoff solenoid should
click audibly to indicate that the valve is open.
8065-019
Turn to START position
8065-045
Turn fuel shut off valve counter clockwise to open.
Propane engines - open one or both fuel
tank valves by turning the valves counter
clockwise.
When the engine starts, immediately release the
10.
ignition key back to the run position.
IMPORTANT INFORMATION
Do not run the starter for more than 5 seconds
each time. If the engine does not start, wait
about 10 seconds before retrying.
8061-001
Release ignition to the RUN position
It is possible to flood a propane fueled engine.
If it occurs, turn the ignition off and shut down
the fuel valves. Fully open the throttle. After a
short interval, turn the fuel valves back on and
repeat the start procedure.