Hearth & Home Technologies • Heat-Zone-240V Air Duct Kit • 299-900D • 7/10

2

FLOOR REGISTER

TWO DUCT KITS

WALL REGISTER

WALL REGISTER

WALL REGISTER

CEILING REGISTER

Figure 2

Possible Air Duct Runs/Locations

2. The Heat-Zone 240V kit is tested and safe when installed

in accordance with this installation manual. This kit is
carefully engineered and must be installed only as speci-
fi ed. Modifying the kit or any of its components will void
the warranty, and may possibly cause a fi re hazard.

3. CAUTION: Installation of this appliance should only be

carried out by an authorized person. All relevant codes
and regulations laid down by the gas piping authorities,
municipal building regulations, electrical wiring regula-
tions and the requirements of the AS5601 Gas Instal-
lation code must be observed.

4. Plan the location of the heater and the warm air duct

run(s).

MAXIMUM Duct Run = 6 M for useful heat output.

MINIMUM Duct Run = NA - for runs out from the heater
to adjacent room OR down to the room below.

MINIMUM Duct Run = 787 mm top of heater to room
above.

COVER

PLATE

DUCT

COLLAR

6000 SERIES

XLR-AU

Installation

1. Remove the cover plate from the side of the heater and

discard it.

2. Center the duct collar around the exposed hole and

attach it to the heater with 3 screws. NOTE: Do this
BEFORE fi nal positioning of the heater. See Figure 3.

Figure 3