Honeywell PRO 1000 User Manual
Page 13

PRO 1000 Series
9
ENG
LISH
In case of difficulty
Screen is blank.
• Check circuit breaker and reset if necessary.
• Ensure the heating/cooling system is powered up.
• Ensure the furnace door is properly closed.
• Ensure two fresh AAA alkaline batteries are correctly installed.
Temperature settings cannot be
changed.
• The System switch is off.
• You are setting the temperatures outside their allowable ranges:
• Heat: 40 °F to 90 °F (4.5 °C to 32 °C).
• Cool: 50 °F to 99 °F (10 °C to 37 °C).
Cool On or Heat On is flashing.
• The compressor protection delay has been activated. Wait for the
delay to end (maximum of 5 minutes).
HI appears on the screen.
• The ambient (measured) temperature is above 122 °F (50 °C).
LO appears on the screen.
• The ambient (measured) temperature is below 32 °F (0 °C).
E1 appears on the screen.
• The temperature sensor circuit is opened. Replace the thermostat.
E2 appears on the screen.
• The temperature sensor circuit is shorted. Replace the thermostat.
400-626-002-D (69-1971EFS-03 non-prog TH1110D_TH1210D user manual).book Page 9 Thursday, April 16, 2009 3:29 PM