beautypg.com

Replaced (see section 6-4) – Hobart Welding Products AIRFORCE ICE-27C User Manual

Page 25

background image

OM-203 653 Page 21

6-4. Checking/Replacing Retaining Cup, Tip, And Electrode

Overtightening will strip threads. Do not overtighten retaining cup during

assembly. Do not cross-thread parts causing stripping. Use care during torch

assembly and parts replacement.

Inspect shield cup, tip, and electrode for wear before cutting or whenever cutting speed has been significantly

reduced. Do not operate torch without a tip or electrode in place. Be sure to use genuine replacement parts.

A good practice is to replace both the tip and electrode at the same time.

802 465

Turn Off power source.
1

Shield Cup

2

O-Ring

Remove shield cup. Check cup for cracks,

and replace if necessary.
Check O-ring for cracks or worn spots, re-

place shield cup if necessary.
3

Tip

4

Opening

Remove tip. Check tip, and replace if open-

ing is deformed or 50% oversize. If inside of

tip is not clean and bright, clean with steel

wool. Be sure to remove any pieces of steel

wool afterwards.
5

Electrode

Check electrode. If center has a pit more

than a 1/16 in (2 mm) deep, remove and re-

place electrode.
6

Swirl Ring

7

O-Ring

Remove swirl ring. Check ring, and replace

if side holes are plugged.
Check O-ring for cracks or worn spots,

replace swirl ring if necessary.
8

O-Ring

Check O-ring for cracks or worn spots, and

replace if necessary.
Carefully reassemble parts in reverse order.

Make sure this area is clean of

any debris.

Make sure swirl ring is clean of any

debris and no holes are obstructed.

Turn Off power source before checking torch parts.

New

Worn

New

Worn

5

1/16 in

(2 mm)

Pit

4

3

6

1

2

7

8