beautypg.com

Installing the ceiling plate – Hunter Fan 41844-01 User Manual

Page 4

background image

41844-01 12/20/2002

© 2002 Hunter Fan Company

4

44

4

4

cutting the ceiling hole

1.

Locate the site for the hole directly below the joist or support
brace that will hold the outlet box and fan.

2.

Cut a 4" diameter hole through the drywall or plaster of the
ceiling as shown in Figure 5. You will use the hole to install the
support brace and outlet box.

F

FF

FFiiiiig

gg

ggur

ur

ur

ur

ure 5 - C

e 5 - C

e 5 - C

e 5 - C

e 5 - Cu

u

u

u

uttttttttttin

in

in

in

ing t

g t

g t

g t

g th

h

h

h

he c

e c

e c

e c

e ce

ee

eeilin

ilin

ilin

ilin

iling h

g h

g h

g h

g ho

o

o

o

ollllle

ee

ee

installing the support brace

If there is a ceiling joist directly above the hole which will allow the
outlet box to be recessed a minimum of 1/16" in the ceiling, go to
in

in

in

in

insssssttttta

aa

aallin

llin

llin

llin

lling t

g t

g t

g t

g th

h

h

h

he o

e o

e o

e o

e ou

u

u

u

utttttllllle

ee

eet b

t b

t b

t b

t bo

o

o

o

ox

xx

xx section.

If there is not an adequate ceiling joist available, do the following:
1.

Attach a 2" x 4" support brace between two joists. The sup-
port brace must allow the bottom of the outlet box to be re-
cessed a minimum of 1/16" into the ceiling. See Figure 6.

2.

Check the support brace to ensure it will support the full weight
of the fan and light kit.

installing the outlet box

1.

Obtain a UL-approved octagonal 4" x 1-1/2" outlet box, plus
two #8 x 1-1/2" wood screws and washers, available from any
hardware store or electrical supply house.

2.

Orient the outlet box so that both the inner and outer holes in
the box align with the joist or support brace.

3.

Drill pilot holes no larger than the minor diameter of the wood
screws (5/64") through the inner holes of the outlet box.

4.

Attach the outlet box directly to the support brace or joist
with two #8 x 1-1/2" wood screws and washers. The bottom of
the outlet box must be recessed a minimum of 1/16" into the
ceiling as shown in Figure 6.

F

FF

FFiiiiig

gg

ggur

ur

ur

ur

ure 7 - I

e 7 - I

e 7 - I

e 7 - I

e 7 - In

n

n

n

nsssssttttta

aa

aallin

llin

llin

llin

lling t

g t

g t

g t

g th

h

h

h

he o

e o

e o

e o

e ou

u

u

u

utttttllllle

ee

eet b

t b

t b

t b

t bo

o

o

o

ox

xx

xx

preparing the wiring

C

C

C

C

CA

A

A

A

AU

U

U

U

UT

T

T

T

TIIIIIO

O

O

O

ON: A

N: A

N: A

N: A

N: All w

ll w

ll w

ll w

ll wir

ir

ir

ir

irin

in

in

in

ing mu

g mu

g mu

g mu

g mussssst b

t b

t b

t b

t be in a

e in a

e in a

e in a

e in acccccccccco

o

o

o

orrrrrd

d

d

d

da

aa

aan

n

n

n

nccccce w

e w

e w

e w

e wiiiiittttth n

h n

h n

h n

h na-

a-

a-

a-

a-

tttttiiiiio

o

o

o

on

n

n

n

na

aa

aal a

l a

l a

l a

l an

n

n

n

nd l

d l

d l

d l

d lo

o

o

o

occccca

aa

aal e

l e

l e

l e

l ellllle

ee

eeccccctttttrrrrriiiiicccccaaaaal c

l c

l c

l c

l co

o

o

o

od

d

d

d

de

ee

ees a

s a

s a

s a

s an

n

n

n

nd A

d A

d A

d A

d AN

N

N

N

NS

SS

SSI/N

I/N

I/N

I/N

I/NF

FF

FFP

P

P

P

PA 70. I

A 70. I

A 70. I

A 70. I

A 70. If y

f y

f y

f y

f yo

o

o

o

ou

u

u

u

u

a

aa

aarrrrre un

e un

e un

e un

e unfffffa

aa

aam

m

m

m

mili

ili

ili

ili

ilia

aa

aar w

r w

r w

r w

r wiiiiittttth w

h w

h w

h w

h wir

ir

ir

ir

irin

in

in

in

ing

gg

gg, y

, y

, y

, y

, yo

o

o

o

ou s

u s

u s

u s

u sh

h

h

h

ho

o

o

o

oul

ul

ul

ul

uld u

d u

d u

d u

d ussssse a q

e a q

e a q

e a q

e a qu

u

u

u

ua

aa

aali

li

li

li

lifffffiiiiie

ee

eed e

d e

d e

d e

d ellllle

ee

eeccccc-----

tttttrrrrriiiiic

cc

cciiiiiaaaaan

n

n

n

n.....

1.

Make sure the circuit breakers to the fan supply line leads and
associated wall switch location are turned off. If you cannot
lock the circuit breakers in the off position, securely fasten a
prominent warning device, such as a tag, to the service panel.

2.

Thread the fan supply line through the outlet box so that the
fan supply line extends at least 6" beyond the box as shown in
Figure 7.

3.

Attach the fan supply line to the outlet box with an approved
connector, available at any hardware store or electrical supply
house. Refer to Figure 7.

4.

Make certain the wiring meets all national and local standards
and ANSI/NFPA 70.

F

FF

FFiiiiig

gg

ggur

ur

ur

ur

ure 7 - Pr

e 7 - Pr

e 7 - Pr

e 7 - Pr

e 7 - Pre

ee

eep

p

p

p

pa

aa

aarrrrrin

in

in

in

ing t

g t

g t

g t

g th

h

h

h

he w

e w

e w

e w

e wir

ir

ir

ir

irin

in

in

in

ing

gg

gg

You have now successfully prepared your ceiling fan site. For in-
structions on how to install your ceiling fan, continue with the in-

in-

in-

in-

in-

sssssttttta

aa

aallin

llin

llin

llin

lling t

g t

g t

g t

g th

h

h

h

he c

e c

e c

e c

e ce

ee

eeilin

ilin

ilin

ilin

iling p

g p

g p

g p

g pllllla

aa

aattttteeeee section.

installing the ceiling plate

1.

Drill two pilot holes into the wood support structure through
the outermost holes on the outlet box. The pilot holes should
be 9/64" in diameter.

2.

Thread the lead wires from the outlet box through the hole in
the middle of the ceiling plate.

3.

Your fan comes with four neoprene noise isolators. Position
the isolators between the ceiling plate and ceiling by inserting
the raised areas on each isolator into the holes in the ceiling
plate. Refer to Figure 8.

F

FF

FFiiiiig

gg

ggur

ur

ur

ur

ure 8 - I

e 8 - I

e 8 - I

e 8 - I

e 8 - In

n

n

n

nssssse

ee

eerrrrrtttttin

in

in

in

ing t

g t

g t

g t

g th

h

h

h

he i

e i

e i

e i

e issssso

o

o

o

ollllla

aa

aattttto

o

o

o

orrrrrs in

s in

s in

s in

s inttttto t

o t

o t

o t

o th

h

h

h

he c

e c

e c

e c

e ce

ee

eeilin

ilin

ilin

ilin

iling p

g p

g p

g p

g pllllla

aa

aattttteeeee

4”
Diameter
Ceiling
Hole

Ceiling

Ceiling Joist

Support Brace

Support Brace

Outlet Box

1/16” Recess

Washer

Wood Screw

Approved
Connector

Wire Leads

Isolators

Ceiling Plate