4-17. Remote 14 Receptacle Information

Place Welder Selector switch in Welder A/Welder B position (dual operator mode) for
both remote receptacles to work. Welder A (left) remote receptacle output contactor
and control is disabled when switch is in Welder B position.

NOTE

Socket*

Socket Information

24 VOLTS AC

A

24 volts ac. Protected by circuit breakers CB5 and CB6.

B

Contact closure to A completes 24 volts ac contactor control circuit.

C

Output to remote control; +10 volts dc in CV, 0 to +10 volts dc in CC.

REMOTE

OUTPUT

D

Remote control circuit common.

CONTROL

E

0 to +10 volts dc input command signal from remote control.

A/V

AMPERAGE

VOLTAGE

F

H

Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes.

Voltage feedback; +1 volts dc per 10 arc volts.

115 VOLTS AC

I

J

115 volts, 15 amperes, 60 Hz ac. Protected by circuit breakers CB5 and CB6.

Contact closure to I completes 115 volts ac contactor control circuit.

K

Chassis common.

GND

G

Circuit common for 24 and 115 volts ac circuits.

*The remaining sockets are not used.