17. remote 14 receptacle information – Hobart Welding Products OM-494 User Manual
Page 31
OM-494 Page 27
4-17. Remote 14 Receptacle Information
Place Welder Selector switch in Welder A/Welder B position (dual operator mode) for
both remote receptacles to work. Welder A (left) remote receptacle output contactor
and control is disabled when switch is in Welder B position.
NOTE
Socket*
Socket Information
24 VOLTS AC
A
24 volts ac. Protected by circuit breakers CB5 and CB6.
B
Contact closure to A completes 24 volts ac contactor control circuit.
C
Output to remote control; +10 volts dc in CV, 0 to +10 volts dc in CC.
REMOTE
OUTPUT
D
Remote control circuit common.
CONTROL
E
0 to +10 volts dc input command signal from remote control.
A/V
AMPERAGE
VOLTAGE
F
H
Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes.
Voltage feedback; +1 volts dc per 10 arc volts.
115 VOLTS AC
I
J
115 volts, 15 amperes, 60 Hz ac. Protected by circuit breakers CB5 and CB6.
Contact closure to I completes 115 volts ac contactor control circuit.
K
Chassis common.
GND
G
Circuit common for 24 and 115 volts ac circuits.
*The remaining sockets are not used.