Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08
48
D. Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
Figure 12.2 Intellifi re Pilot Ignition (IPI) Wiring Diagram
WARNING! Risk of Shock! Replace damaged wire with
type 105º C rated wire. Wire must have high temperature
insulation.
Note: Appliance will not operate
unless properly grounded.
PLUG-IN
3V TRANSFORMER
ON/OFF
WALL SWITCH
IGNITION
MODULE
(3V)
VALVE
NEUTRAL
GROUND
LOW VOLTAGE
SEE NOTE 1
REMOTE
CONTROL
HOT
PLUG-IN
REMOTE
JUMPER WIRE
ORG
GR
N
BRN
BRN
RED
BLK
INTERMITTENT
PILOT IGNITOR
ORG
WHT
IGNITION MODULE 3 VAC
TRANSFORMER
VALVE
3 VAC
THERMOSTAT
WIRE
ASSEMBLY
BLACK WIRE CAN BE
PLUGGED INTO ANY
OF #1 - #5 LOCATIONS
ON THE HOT SIDE
WHITE WIRE CAN BE
PLUGGED INTO ANY
OF#1 - #5 LOCATIONS
ON THE NEUTRAL SIDE
GROUND TO
FIREPLACE
CHASSIS*