beautypg.com

Wiring for grounds, power, and rf, Conduit – Honeywell 800-04433V1 User Manual

Page 7

background image

iPGSM-COM Commercial Fire Communicator – Installation and Setup Guide

– 5 –

iPGSM-C0M-001-V0

TB 1

6
7
8

5

10
11

9

2
3
4

1

FOR EXTERNAL ANTENNA
50 OHM MMCX ONLY

PRIMARY POWER: 9 - 16.5 VAC
CURRENT: 900mA PEAK, 70mA STANDBY
BATTERY: 8V. 3.1 AHr FOR 24 Hr BACKUP

FCC:XXXXXXXXXX IC: YYYYYYYYYY

RSSI

M0

M1

GPRS

IBS

7720P PROGRAMMER PORT
NOT FOR TELEPHONE SERVICE USE!

BATTERY

ANTENNA
MOUNTING
ADAPTER

CONDUIT

WALL OUTLET BOX
(K14358)

CABINET
DOOR

PowerBoost1

TO FACILITY
GROUND

ANTENNA

NUT,
WASHER

50 OHM
CABLE

LED
Display

TRANSFORMER (N8167)

1

5

ON

2 3 4

CONDUIT

FUSE

+

(not supplied)

BATTERY

7AH

Dialer Capture Module

Telco 1

Telco 2

ECP

Tip 2

Ring 2

ZN-

EOL

EOL

ZN+

PWR

GND

Tip 1

Ring 1

Data Out

Data In

12V In

GND

Data Out

RED

GREEN

iGSM Comm Module

Wiring for Grounds, Power, and RF