can carry a higher current than a 16
gauge cord.
(See table A.)
When using more than one exten-
4.
sion cord to make up the total length,
make sure each cord contains at least
the minimum wire size required.
(See
table A.)
If you are using one extension cord
5.
for more than one tool, add the name-
plate
amperes and use the sum to
determine the required minimum cord
size.
(See table A.)
If you are using an extension cord
6.
outdoors, make sure it is marked with
the suffix “W-A” (“W” in Canada) to
indicate it is acceptable for outdoor
use.
Make sure the extension cord is
7.
properly wired and in good electrical
condition. Always replace a damaged
extension cord or have it repaired by
a qualified electrician before using it.
Protect the extension cords from
8.
sharp objects, excessive heat, and
damp or wet areas.
recommended minimum wire
gAuge For eXtenSion cordS*
(120/240 VOLT)
nAmeplAte
AmpereS
(at full load)
eXtenSion cord
length
25’
50’
75’
100’
150’
0 – 2.0
18
18
18
18
16
2.1 – 3.4
18
18
18
16
14
3.5 – 5.0
18
18
16
14
12
5.1 – 7.0
18
16
14
12
12
7.1 – 12.0
18
14
12
10
-
12.1 – 16.0
14
12
10
-
-
16.1 – 20.0
12
10
-
-
-
tABle A
* Based on limiting the line
voltage drop to five volts at
150% of the rated amperes.
Symbology