Harbor Freight Tools 98870 User Manual
Page 8
Page 8- SKU: 98870
installing the power plug
note: This Arc Welder is equipped to operate with either 115 or 30 Volt power supply.
Standard “household” current in the U.S. is 110-10 Volts. If you will be using a
“household” outlet, follow directions for 115 Volt wiring. Electric service for applianc-
es such as stoves in the U.S. are 0-40 Volts. If you will be using an “appliance”
outlet, follow directions for 30 Volt wiring. If you have ANY DOUBT, consult a quali-
fied electrician. Severe damage can result from improperly wiring this Arc Welder.
Determine which voltage you will be using, and secure a UL approved plug for the
selected voltage which will fit your wall outlet.
Identify the correct wires you will be using for your voltage from the chart below.
115 Volt installation 230 Volt installation
Ground
Green
Green
Neutral
White
Hot
Black L1
Black L1, Red L
Tied Off Wire Red
White
Prepare the wires by stripping approximately 1/” of the insulation from the end of
each wire.
Depending on the plug design, insert the prepared cable ends into the plug from the
back.
Attach the Green wire to the Ground pole of the plug.
Wire the appropriate plug as shown in # above.
To tie off the wire shown in # above: Using a Wire Nut, cap the bare end of the un-
used wire, carefully insulating it from contact with any metal or conducting surface.
WArning! Before operating this welder, make sure that the plug is properly wired for
the voltage to be used, AND that the SELECTOR SWITCH (1) is set for the proper
voltage. The Selector Switch must be set before the Arc Welder is plugged in and
turned on. Severe equipment failure and property damage can result from improper
wiring or switch selection.
WArning! If Arc Welder is operated at 115 V~, be sure not to regulate the current over 70
A, or the 30 A breaker in your house line will trip.
1.
.
3.
4.
5.
6.
7.