Motor Brushes

NOTE: Replace brushes when worn to about 0.5 in.

(12.5 mm). Always check both brushes. Brush Repair

Kit 236967, which includes spring clip 112766, is

available for motors manufactured by Pacific Scientific.

NOTE: Replacement brushes may last only half as

long as the original ones. To maximize brush life, break

in new brushes by operating the sprayer for at least

one hour with no load (remove the pump connecting

rod pin).

WARNING

INJECTION HAZARD

To reduce the risk of serious injury,

whenever you are instructed to relieve

pressure, follow the

Pressure Relief

Procedure on page 9.

1. Remove both inspection covers (A) and their

gaskets. See Fig 14.

Fig. 14

A

04653

2. Push in the spring clip (F) and release its hook (G)

from the brush holder (B). Pull out the spring clip.

See Fig 15.

3. Slide off the brush lead terminal (E) off the blade

connector. Remove the old brush (C). See Fig 15.

Fig. 15

F

G

E

D

C

B

H

1

1

Motor lead; do not disconnect

2

Minimum 0.5” (12.5 mm)

03881

3

Included in Brush Repair

Kit 236967

3

2

4. Inspect the commutator for excessive pitting,

burning or gouging. A black color on the commuta-

tor is normal. Have the commutator resurfaced by

a qualified motor repair shop if the brushes seem

to wear too fast or arc excessively. See Step 9.d.,

also.

5. Repeat for the other side.

NOTE: The motor brushes on the other side are

upside down.

6. Place a new brush (C) in the holder (B) so the

ramp (H) faces the spring. See Fig. 16.

Fig. 16

03881

1

G

C

E

F

7. Holding the spring clip (F) at a slight angle, slide

the spring clip into the brush holder and hook it

over the end of the holder. See Fig. 16. Pull on the

spring clip to be sure it stays in place. Connect the

brush lead to the blade connector (E).

8. Repeat for the other side.