Section 6 − maintenance & troubleshooting, 1. routine maintenance, 3 months – Hobart Welding Products STICKMATE OM-950 User Manual
Page 23: 6 months 12 months
OM-950 Page 19
SECTION 6 − MAINTENANCE & TROUBLESHOOTING
6-1. Routine Maintenance
Y Disconnect power before maintaining.
3 Months
Replace
Unreadable
Labels
Repair Or
Replace
Cracked
Cables
6 Months
12 Months
Blow Out Or Vacuum
Inside,
During Heavy Service,
Clean Monthly
OR
Lubricate Shunt Block
6-2. Lubricating Shunt Block And Anti-Noise Adjustment
802 248-D
Y Turn Off welding power
source and disconnect input
power.
1
Wrapper
Remove wrapper.
2
Shunt Block
.
Do not grease screw threads
on shunt block.
Apply light coating of high-tempera-
ture grease to shaded areas of both
shunt blocks. Turn amperage con-
trol handle to spread grease evenly.
3
Noise Adjustment Screws
If shunt block vibrates and
becomes noisy, tighten adjustment
screws 1/4 turn. Install wrapper,
turn On unit, and check for shunt
noise. Repeat procedure until noise
stops. Do not overtighten. Call your
nearest Factory Authorized Ser-
vice Agent if noise continues.
Y Install wrapper before
turning On power.
5/16, 3/8 in
2
3
2
Tools Needed:
1/2 in
1