Henny Penny HHC-993 User Manual
Page 20

Model HHC-990
4-3. SPECIAL PROGRAMMING
This mode allows you to program the following:
SP-1
• Fahrenheit/celsius
SP-2
• Lock/unlock
SP-3
• Air temperature setpoint
SP-4
• Humidity setpoint
SP-5
• Proof air temperature
SP-6
• Proof humidity setpoint
SP-7
• Out of water tripp point
SP-8
• Clean water pan setpoint
SP-9
• System intialization
SP-10 • Audio volume
SP-11 • Audio tone
SP-12 • Audio effects
SP-13 • Language options
SP-1 Fahrenheit/Celsius
1. Press and hold the
until “LEVEL 2”, then “CLOCK SET”
shows in the display.
2. Press again, then “SP PROG” shows in display.
3. After 5 seconds, “ENTER CODE” shows in display.
4. Press
and “SP-1, TEMP, UNITS” and
“
o
F”or
“o
C” shows in the display.
5. Press the
to change temperature units.
SP-2 Lock/Unlock
6. Press and “SP-2, LOCK/UNLOCK PROGRAMMING’
shows in display, along with either “LOCK” or “UNLOCK”.
7. Press
to change lock the programming or unlock the
programming.
SP-3
Air Temperature Setpoint
8. Press and “SP-3, AIRTEMP SETPOINT,” and the
preset cabinet temperature shows in display.
9. Press
to change the air temperature setpoint,
140
o
F (60
o
C) minimum, 210
o
F (99
o
C) maximum.
303