![background image](/manuals/94241/24/background.png)
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09
24
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
H
1
V
1
Figure 7.3
Figure 7.4
One Elbow
Two Elbows
Top Vent - Horizontal Termination
V
1
Minimum
H
1
Maximum
1 ft.
305 mm
3 ft.
914 mm
2 ft.
610 mm
6 ft.
1.8 m
3 ft.
914 mm
9 ft.
2.7 m
4 ft.
1.2 m
12 ft.
3.7 m
V
1
+ H
1
= 40 ft. (12.2 m) Maximum
H
1
= 20 ft. (6.1 m) Maximum
V
1
= 1 ft. (305 mm) Minimum
V
1
Minimum
H
1
+ H
2
Maximum
1 ft.
305 mm
Cannot do
1 1/2 ft.
457 mm
1-1/2 ft.
457 mm
2 ft.
610 mm
3 ft.
914 mm
3 ft.
914 mm
6 ft.
1.8 m
4 ft.
1.2 m
9 ft.
2.7 m
V
1
+ H
1
+ H
2
= 50 ft. (15.2 m) Maximum
H
1
+ H
2
= 17 ft. (5.2 m) Maximum
V
1
= 1 ft. (305 mm) Minimum
E. Vent Diagrams