69-0638—1

6

SET TEMPERATURE CONTROL LEVERS

The two levers on top of the thermostat control the low

and high temperatures for energy savings and comfort con-
trol (Fig. 12). The lever on the left (blue mark) controls the
lower temperature. The lever on the right (red mark) controls
the higher temperature.

We recommend pushing the levers together at an appro-

priate temperature for either heat or cool until the occupant
programs the thermostat and makes the final temperature
selections.

Fig. 12—Temperature control levers.

50

60

70

80

HIGH TEMPERATURE
(RED MARK)
SET LEVER

LOW TEMPERATURE
(BLUE MARK)
SET LEVER

M859

SET SUBBASE SWITCHES (IF APPLICABLE)

The subbase system switch controls system operation as

follows:

HEAT: Heating system is controlled by the thermostat.

Cooling system is off.

COOL: Cooling system is controlled by the thermostat.

Heating system is off.

OFF: Both the heating and cooling systems are off. If the

fan switch is in the AUTO position, the fan is also off.

The subbase fan switch controls fan operation as follows:
ON: Fan operates continuously.
AUTO: Fan operates with the cooling equipment as con-

trolled by the thermostat or with the heating equip-
ment as controlled by the plenum switch. In electric
heat, heat pump and fan coil systems, the fan is con-
trolled by the thermostat in heating and cooling.

To switch positions, use thumb or index finger to slide

lever to the desired position. For proper circuit operation,
switch lever must stop in detent over the desired function
indicator mark.

Checkout

CAUTION

Do not check operation by shorting across termi-
nals of system controls. This will damage the heat
anticipator.

HEATING-ONLY SYSTEM

Turn on power to the furnace.
Push both temperature setting levers together at least 5

° F

[3

° C] above the room temperature. The main burner should

come on. The fan will start when the furnace heats up.

Move both levers 5

° F [3° C] below the room tempera-

ture. The burner should shut off.

Operate the entire heating system at least one complete

cycle.

If thermostat fails any test, refer to the Troubleshooting

Guide in the Owner’s Manual.

Reset both the temperature setting levers to the desired

temperatures.

COOLING-ONLY SYSTEM (T8095A ONLY)

Turn on power to the cooling equipment.
Push both temperature setting levers together at least 5

° F

[3

° C] below the room temperature. The cooling equipment

will operate, and the fan will start. Allow for any time delay
that may be built into the compressor control circuit.

NOTE: To avoid compressor damage, do not operate the

system when outdoor temperature is below 50

° F [10° C].

Refer to manufacturer recommendations.

Move both levers 5

° F [3° C] above room temperature.

The cooling equipment and the fan should shut off.

Operate the entire cooling system at least one complete

cycle.

If thermostat fails any test, refer to the Troubleshooting

Guide in the Owner’s Manual.

Reset both the temperature setting levers to the desired

temperatures.

HEATING/COOLING SYSTEM

Turn on power to the furnace and cooling system.
Place the system switch lever to HEAT and fan switch

lever to AUTO.

Push both temperature setting levers together at least 5

° F

[3

° C] above room temperature. The main burner should

come on. The fan will start when the furnace heats up. (If
central electric heat, fan coil or heat pump system, fan starts
immediately.)

Move both levers 5

° F [3° C] below room temperature.

The burner should shut off.

Place the system switch lever to COOL and the fan switch

lever to AUTO. The cooling equipment will operate, and the
fan will start. Allow for any time delay that may be built into
the compressor control circuit.

NOTE: To avoid compressor damage, do not operate the

system when outdoor temperature is below 50

° F [10° C].

Refer to manufacturer recommendations.

Move both temperature setting levers together at least 5

° F

[3

° C] above the room temperature. The cooling equipment

should shut off.

Place the fan switch to ON. The fan should run continu-

ously with the system switch in any position.

Place the system switch to OFF. Move both temperature

setting levers to various positions. The heating and cooling
systems should not operate.

Operate the entire system for at least one complete cycle

with the system switch at COOL and one complete cycle
with the switch at HEAT.

If thermostat fails any test, refer to the Troubleshooting

Guide in the Owner’s Manual.

Reset both the temperature setting levers to the desired

temperatures.

Leave Owner’s Manual and Assistance Information in a

convenient place for the building occupant or provide with
other appliance manuals.