beautypg.com

Operation – Harman Stove Company PF 100 User Manual

Page 25

background image

25

PF100

4. If starting after an empty hopper, turn
Feed Adjuster to "TEST"
(for one 60
second cycle).

This will purge pellets into

the auger tube and also allow you to check
the motors for operation. NOTE: The auger
motor will not operate with the ash door
open.

L

OW

F

UEL

65

60

75

80

70

5. Turn Feed Adjuster to #4.

If this is your first fire or you are trying

different pellets, set the feed adjuster to #4,
Fig. 50 This is a conservative number and
will probably need to be increased if maxi-
mum BTU output is desired. After you know
a feed rate setting that works well for your
application, use that setting. Remember, if
your feed rate is too high you may waste fuel
due to overshooting the Wall Control setting.

6. Flip the Igniter Switch up into the
"AUTO-LIGHT" position.

7. Turn the Temperature Dial on the wall
control to desired room temperature. Note:
The set temperature on the dial must be higher
than the room temperature for the fire to light.

Fig. 49

Fig. 50

Fig. 51

Fig. 52

WARNING: HOT WHILE IN OPERATION.
KEEP CHILDREN, CLOTHING, AND
FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS.

Operation