FUNCTIONAL DESCRIPTION

Specifications

Operating Air

Pressure

70-120 PSI

Max. Air Pressure

120 PSI

Air Consumption

.5 CFM @ 90 PSI

Air Inlet

1/4” -18 NPT

Fastener Capacity 3/8” to 2” 18 Gauge Brad Nails
Magazine Capacity 100 Fasteners
Safety

Full Sequential Trip Safety

Components and Controls

Safety Nosepiece - Also called the workpiece

contact, the Safety Nosepiece helps

prevent the tool from firing unless it is

pressed against an object.

INITIAL TOOL SET UP/

ASSEMBLY

Read the ENTIRE IMPORTANT

SAFETY INFORMATION

section at the beginning of this

manual including all text under

subheadings therein before set up

or use of this product.

Note: For additional information regarding the

parts listed in the following pages, refer

to the Assembly Diagram near the end of

this manual.

Unpacking

When unpacking, make sure that the

item is intact and undamaged. If any parts

are missing or broken, please call Harbor

Freight Tools at 1-800-444-3353 as soon as

possible.

• This air tool may be shipped with a

protective plug covering the air inlet.

Remove this plug before set up.

Air Supply

TO PREVENT

EXPLOSION:

Use only clean, dry, regulated,

compressed air to power this

tool. Do not use oxygen, carbon

dioxide, combustible gases, or

any other bottled gas as a power

source for this tool.

1. Connect a regulator valve, an in-line shut

off valve and 1/4” NPT air hose (all sold

separately) to the Quick Coupler. Use

thread tape for all threaded connections.

The air hose must be long enough to

reach the work area with enough extra

length to allow free movement while

working.

An in‑line shutoff ball valve

is an important safety device because

it controls the air supply even if the

air hose is ruptured. The shutoff

valve should be a ball valve because

it can be closed quickly. See pages 8

and 9 for Air Tool Setup procedures.

Note: If an automatic oiler system is not

used, add a few drops of Pneumatic

Tool Oil into the airline connection before

operation. Add a few more drops after

each hour of continual use.

Safety (26)

Air Deflector

(3)

Air Inlet

Plug (63)

Trigger

(36)

Latch

(58)

Functional Description