Functional description, Initial tool set up/ assembly – Harbor Freight Tools 18 GAUGE BRAD NAILER 68021 User Manual
Page 7
Page 7
For technical questions, please call 1‑800‑444‑3353.
SKU 68021
FUNCTIONAL DESCRIPTION
Specifications
Operating Air
Pressure
70-120 PSI
Max. Air Pressure
120 PSI
Air Consumption
.5 CFM @ 90 PSI
Air Inlet
1/4” -18 NPT
Fastener Capacity 3/8” to 2” 18 Gauge Brad Nails
Magazine Capacity 100 Fasteners
Safety
Full Sequential Trip Safety
Components and Controls
Safety Nosepiece - Also called the workpiece
contact, the Safety Nosepiece helps
prevent the tool from firing unless it is
pressed against an object.
INITIAL TOOL SET UP/
ASSEMBLY
Read the ENTIRE IMPORTANT
SAFETY INFORMATION
section at the beginning of this
manual including all text under
subheadings therein before set up
or use of this product.
Note: For additional information regarding the
parts listed in the following pages, refer
to the Assembly Diagram near the end of
this manual.
Unpacking
When unpacking, make sure that the
item is intact and undamaged. If any parts
are missing or broken, please call Harbor
Freight Tools at 1-800-444-3353 as soon as
possible.
• This air tool may be shipped with a
protective plug covering the air inlet.
Remove this plug before set up.
Air Supply
TO PREVENT
EXPLOSION:
Use only clean, dry, regulated,
compressed air to power this
tool. Do not use oxygen, carbon
dioxide, combustible gases, or
any other bottled gas as a power
source for this tool.
1. Connect a regulator valve, an in-line shut
off valve and 1/4” NPT air hose (all sold
separately) to the Quick Coupler. Use
thread tape for all threaded connections.
The air hose must be long enough to
reach the work area with enough extra
length to allow free movement while
working.
An in‑line shutoff ball valve
is an important safety device because
it controls the air supply even if the
air hose is ruptured. The shutoff
valve should be a ball valve because
it can be closed quickly. See pages 8
and 9 for Air Tool Setup procedures.
Note: If an automatic oiler system is not
used, add a few drops of Pneumatic
Tool Oil into the airline connection before
operation. Add a few more drops after
each hour of continual use.
Safety (26)
Air Deflector
(3)
Air Inlet
Plug (63)
Trigger
(36)
Latch
(58)
Functional Description