Honeywell Y8196A User Manual
Page 6

69-0637—2
6
Fig. 11—Typical hookup for Y8196A Package (T8196A Thermostat/Q682A Subbase) in heating/cooling
system.
HEAT
OFF
COOL
ON
AUTO
H
C
FAN
SWITCH
THERMOSTAT
BATTERIES
SUBBASE
M2386A
HEAT
ANTICIPATOR
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
REMOTE INDICATION FOR FILTER OPTIONAL.
JUMPER W TO Y FOR HEAT PUMP COMPRESSOR CONTROL.
1
COOL
ANTICIPATOR
HEAT
ANTICIPATOR
SYSTEM
SWITCH
HEAT
OFF
COOL
O
G
Y
W
B
R
REVERSING
VALVE/
COOLING
DAMPER
REVERSING
VALVE/
HEATING
DAMPER
FAN
RELAY
HEAT
RELAY
COMPRESSOR
CONTACTOR
1
L2
L1
(HOT)
2
2
TIMER
3
3
FALL
H
C
FALL
FILTER
LIGHT
SWITCH
Automation and Control Solutions
Honeywell International Inc.
Honeywell Limited—Honeywell Limitée
1985 Douglas Drive North
35 Dynamic Drive
Golden Valley, MN 55422
Scarborough, Ontario M1V 4Z9
69-0637—2