SPECIFICATIONS – 
 
 DIMENSIONS 
 
Exterior
Model
Length Width
Height
GSVM-4060
40"
30
5/8" 60"
GSVM-4072
40"
30
5/8" 72"
GSVM-5272
52"
30
5/8" 72"
ELECTRICAL
 
MODEL NO. Volts/Hz/Phase 
REFRIGERANT
RUN FUSE POWER
TYPE
AMPS
AMPS
CORD
GSVM4060
115/60/1
R-134a 15
20
YES
GSVM4072
115/60/1
R-134a 17
25
NO
GSVM5272
115/60/1
R-134a 20
25
NO
GSVM5272 115/60/1
R-404A
17.25 25
NO **
 
** The GSVM-5272 changed to R404A in January 2000. Check the Serial Plate to verify 
the correct refrigerant. 
 
Note: Applies to the GSVM4072 & 5272 Models Only-Drain Plumbing hookup 
recommended. Optional condensate is available if there is no access to drain plumbing. 
Condensate pan must be field installed and requires a dedicated 15 amp, 120-volt circuit. 
See page 15 for optional drain pan specifications. 
 
 
 BTU 
CAPACITY
 
 
RATING TEMPERATURE ºF
BTU/HR
EVAP
COND
AMBIENT
 
GSVM-4060 
6200
20
110
90
GSVM-4072
6250
20
110
90
GSVM-5272
6300
20
110
90
 
 
Cabinets use R-134A or R-404A
 
SHELVING MAXIMUM WEIGHT CAPACITY (LBS) - 
 
 
The following is a tabulation of the maximum evenly distributed weights that can be
applied on the respective shelves. They greatly exceed most normal food products that 
could be displayed in the case 
 
 
 
 