Installation, Warning, Typical installation – Hitachi 308640 User Manual
Page 4: Ventilate the spray booth

4 308640
Installation
KEY
A
Air Line Filter
B
Air Line Lubricator
C*
Bleed-type Air Shutoff Valve
D
Pump Air Regulator
E*
Fluid Drain Valve
F
Fluid Shutoff Valve
G
Fluid Filter
H*
Grounded Fluid Hose
J
Pump
K
Air Line
L
Air Pressure Regulator
M
Pump Fluid Inlet
N
In-line Fluid Filter
P
Pattern Adjustment Valve Knob
Q*
Fluid Pressure Regulator
R
Pressure Gauge
S
Trigger Safety
T
Pump Runaway Valve
V*
Pump Ground Wire
W
Gun Fluid Connector
X
Air Shutoff Valve
*Equipment required for safe operation of the
system. Must be purchased separately.
Fig. 1
C
A
D
C
B
T
J
V
F
Q
R
G
E
M
H
L
X
K
N
W
S
P
E
05986
Typical Installation
The typical installation shown in Fig. 1 is only a guide
for selecting and installing air-assisted spray systems.
It is not an actual system design. Contact your Graco
distributor for assistance in designing a system to meet
your needs.
Ventilate the Spray Booth
WARNING
TOXIC FLUID HAZARD
To prevent hazardous concentrations of
toxic and/or flammable vapors, spray
only in a properly ventilated spray booth.
Never operate the spray gun unless ventilation
fans are operating.
Check and follow all of the National, State and
Local codes regarding air exhaust velocity require-
ments.