Converting to lp gas, Sealed burner models only), Orifice spuds for converting to lp gas – Hotpoint RGB744 User Manual
Page 45: Aorifice spuds for converting to natural gas, Bconverting surface burners
45
CONVERTING TO LP GAS
(Sealed Burner models only)
or Converting Back to Natural Gas from LP
Orifice Spuds for Converting to LP Gas:
LP orifice spuds are in a small plastic bag packed
with this Use and Care Guide or on a bracket
next to the pressure regulator. LP orifice spuds
have a 2-digit number and the letter “L” on top.
Each orifice spud will also have 1, 2 or 3 grooves
on the top, and some will have a painted side,
denoting the location on the range where it is to
be installed as shown below.
L
L
L
L
A
Orifice Spuds for Converting to Natural Gas:
Natural gas orifice spuds have a 3-digit number
and the letter “N” on the top. Each orifice spud
will also have 1, 2 or 3 grooves on top denoting
the location on the range where it is to be
installed as shown below.
N
N
N
N
B
CONVERTING SURFACE BURNERS
1. Remove grates, burner caps and burner heads.
2. Remove the brass orifice
spud inside the chimney of
each burner using a 9/32
″
or 7 mm nut driver.
3. Install the orifice spuds
according to one of the
following diagrams (see
or
), for LP gas or
natural gas, depending on
which you are converting to.
B
A
3
Front of Range
Front of Range
(continued next page)
Electrode
Drip Pan
(on some models)
Grate
Burner Head
Burner Cap
Orifice spud
Chimney
White
Brown
Brass
Brass
I
III
II
II