45

CONVERTING TO LP GAS

(Sealed Burner models only)

or Converting Back to Natural Gas from LP

Orifice Spuds for Converting to LP Gas:

LP orifice spuds are in a small plastic bag packed
with this Use and Care Guide or on a bracket
next to the pressure regulator. LP orifice spuds
have a 2-digit number and the letter “L” on top.
Each orifice spud will also have 1, 2 or 3 grooves
on the top, and some will have a painted side,
denoting the location on the range where it is to
be installed as shown below.

L

L

L

L

A

Orifice Spuds for Converting to Natural Gas:

Natural gas orifice spuds have a 3-digit number
and the letter “N” on the top. Each orifice spud
will also have 1, 2 or 3 grooves on top denoting
the location on the range where it is to be
installed as shown below.

N

N

N

N

B

CONVERTING SURFACE BURNERS

1. Remove grates, burner caps and burner heads.
2. Remove the brass orifice
spud inside the chimney of
each burner using a 9/32

or 7 mm nut driver.
3. Install the orifice spuds
according to one of the
following diagrams (see
or

), for LP gas or

natural gas, depending on
which you are converting to.

B

A

3

Front of Range

Front of Range

(continued next page)

Electrode

Drip Pan
(on some models)

Grate

Burner Head

Burner Cap

Orifice spud

Chimney

White

Brown

Brass

Brass

I

III

II

II