beautypg.com

Troubleshooting schedule, Keypad, Battery – Husqvarna 536 LIXP User Manual

Page 39: Battery charger, Maintenance

background image

English – 39

MAINTENANCE

Troubleshooting schedule

Keypad

Possible fault codes on the chain saw keypad.

Battery

Troubleshooting the battery and/or the battery charger during charging.

Battery charger

Keypad

Possible faults

Possible action

Warning indicator flashing.

Chain brake engaged.

Pull back the front hand guard to

release the chain brake.

Temperature deviation.

Allow the machine to cool down.

Overload. Cutting attachment
jammed.

The cutting attachment is jammed.
Release the cutting attachment.

The power trigger and the
activate button are pressed at
the same time.

Release the power trigger and the
machine is active.

Green activate LED flashing.

Low battery voltage.

Charge the battery.

Warning indicator lit.

Service

Contact your service agent.

LED display

Possible faults

Possible action

Warning indicator flashing.

The battery is discharged.

Charge the battery

Temperature deviation.

Use the battery in surroundings
where temperatures are between -
10

°C and 40 °C.

Over voltage.

Check that the mains voltage
corresponds with that stated on the
rating plate on the machine.

Remove the battery from the
battery charger.

Warning indicator lit.

Cell difference too much (1V). Contact your service agent.

LED display

Possible faults

Possible action

Warning indicator flashing.

Temperature deviation.

Use the battery charger only when

the surrounding temperature is
between 5

°C and 40 °C.

Warning indicator lit.

Contact your service agent.